Setting the data transmission rate, Configuring the unit as either cpe or coe – Lucent Technologies 7820-0657-001 User Manual

Page 17

Advertising
background image

Setting up the DSLPipe DSU

DSLPipe DSU (SDSL) User’s Guide

2-3

Setting the data transmission rate

To set the DSLPipe DSU data transmission rate, use a pen to move the DIP
switches.Table 2-1 shows the DIP switch settings for each rate. Move the DIP
switch down to turn the switch on. Move a switch up to turn it off.

Configuring the unit as either CPE or COE

If you want the DSLPipe DSU to function as a CPE, leave the fourth DIP switch
in the up (off) position. If you want the unit to function as a COE, move the
fourth DIP switch down.

Note:

JP3 and JP4 must be installed for Dip Switch 4 to be functional.

Table 2-1. Data transmission settings

Rate

DIP Switch 1

DIP Switch 2

DIP Switch 3

144 Kbps

ON

ON

ON

272 Kbps

ON

ON

OFF

400 Kbps

ON

OFF

ON

528 Kbps

ON

OFF

OFF

784

Kbps OFF

ON

ON

1168 Kbps

OFF

ON

OFF

1552 Kbps

OFF

OFF

ON

2320 Kbps

OFF

OFF

OFF