Connection to the Water Supply

- Figures 23, 24

1. Install the shut-off valve, water filter and

automatic shut-off device as required.

Note

The solenoid valve is located at the rear of
your unit.

2. Place a 1/4" OD copper tubing between the

shut-off valve and solenoid valve. Make sure
there is approximately 30" (70 cm) of excess
tubing behind the unit for easy connection.

IMPORTANT

The solenoid valve has a Metric R3/4 male
connection.
A R3/4(metric) to a 1/4" OD adapter and
cable clip are supplied with the icemaker.

Figure

24: Remove the cover cap (4) from

the solenoid valve (1). Install the connection
bracket (2) with sealing ring (6) on the
solenoid valve (1). Attach the copper tube to
the connection bracket (2). Secure the copper
tube (3) to the appliance using the cable
clip (5).

3. Open the shut-off valve for the water supply

and check the entire water system for leaks.
Before the appliance is used for the first time
a licensed plumber should bleed air from the
system.

4. Insert the electrical plug for the combined

winecooler/freezer into the electrical outlet
(Figure 23).

5. Move the combined winecooler-freezer into

final position in the room.

Figure 23