Connection to the Water Supply

1. Install the shut-off valve, water filter and auto-

matic shut-off device as required.

2. The solenoid valve has a Metric R3/4 male con-

nector. A R3/4 (metric) to a 1/4" OD adapter is

supplied with the icemaker.

3. Move the appliance towards the final position

and leave a gap of approx. 30" behind.

4. Insert the water supply line into its intended

opening at the back of the appliance

(Figure

11).

5. Move the power supply line to the area of the

electrical outlet.

Do not connect to the electrical outlet

before the installation is completed

and the water line is connected to the

solenoid valve.

6. Push the appliance slowly to the back wall until

the compressor mounting plate makes contact

with the anti-tipping bracket

(Figure 12).

To prevent the appliance from tipping

forward the compressor mounting plate

must have contact with the anti tipping

bracket (Figure 12).

7. The water line is visible at the front of the appli-

ance. Screw the OD adapter onto the solenoid

valve and connect the water line with the adapt-

er

(Figure 13).

8. Open the shut-off valve for the water supply and

check the entire water system for leaks.