Bluefin compact monitor id and operation, The external monitor consists of three components, Monitor cable – Light & Motion VX2000 User Manual

Page 14: Monitor operation

Advertising
background image

Bluefin Compact Monitor ID and Operation

The External Monitor consists of three components

• External Monitor - provides a 2.5” image of camera view
• Clamp assembly - mounts monitor to back of housing
• Cable - provides video signal from housing to External Monitor

1)

Install monitor by first attaching clamp assembly to back of monitor.

2)

Then attach monitor/clamp assembly to quick connect post by pressing
down and rotating until black sleeve locks into position.

3)

Adjust monitor by rotating clamp assembly (clockwise to tighten, counter
clockwise to loosen).

Monitor Cable

Cable plugs are identical at each end.
Attach by aligning the pins and pressing into the bulkhead until the black
rubber seats.

Use a small amount of silicone grease on connector before
installation to aid against corrosion.

Monitor Operation

Power On/Off
The monitor will power on and off with the camcorder as the power is being
supplied from the camcorder battery. For optimal burn time, we suggest
using the Sony NP750 battery pack on your camcorder.

Monitor Screen
In order to see the camera display information in the monitor screen, you will
need to set the camera to V-Out/LCD on the menu screen. Go to menu, scroll
to ETC, highlight display and set to V-Out/LCD (Refer fig 16). Refer to your
Sony instruction manual. If done correctly, the external monitor will now
display all camcorder view finder information.

27

26

(Fig. 68)

using a 3/32 hex wrench and remove circuit board. (ref. fig. 31)

5)

Feed Bulk Head cable through Bulk Head port. (ref. fig. 32)

6)

Perform o-ring inspection on Bulk Head o-ring.

7)

Insert Bulk Head into Rear Plate until it is firmly seated and o-ring is not
visible.

8)

Tightening bulk head:
A. Straight out bulk head is tightened by turning the bulk head itself with a
3/4” wrench.
B. Right angle bulk head is tightened by attaching the nut provided on the
inside of the Rear Plate or Monitor Back and tighten using a 3/4” wrench.

9)

Attach Bulk Head Cable into the Video Out jack on the Rear Plate circuit
board. (ref. fig. 34)

10) Replace circuit board and secure it to the Rear Plate using the four button

head cap screws.

Infrared leads must guide through their sockets in the
circuit board. Use extra caution to not bend or break these
leads. (ref. fig. 35)

(Fig. 34)

(Fig. 35