7: Network, Line, Tunnel, and Terminal Settings

EDS Device Servers User Guide

54

Line – Configuration Page

Line –
Configuration
Page Settings

Description

Name (optional)

Enter a name for the serial port. The name may have up to 25
characters. Lines with names display in the Login Connect
Menu.

Status

Select to enable or disable the selected EDS serial port.

Protocol

From the drop-down list, select the type of protocol used on the
line. Choices are:

Tunnel = for connecting two serial devices across a network.

LPD = (Line Printer Daemon) for communicating with a printer.

None = use only with CLI and Login Connect Menu.

Interface
(EDS4100 only)

From the drop-down list, select the type of serial interface.
Choices are:

RS232

RS485 Half-Duplex

RS485 Full-Duplex

Baud Rate

Select the baud rate for the currently selected serial port.
Choices are:

300 baud to 230,400 baud. Default is 9600 baud.

Custom = lets you enter in the Custom text box a speed other
than those shown.

Parity

Select the parity used by the currently selected serial line.
Choices are:

None (default)

Even

Odd

Data Bits

Select the number of data bits used by the currently selected
serial line. Choices are:

7

8 (default)

Stop Bits

Select the number of stop bits used by the currently selected
serial line. Choices are:

1 (default)

2

Flow Control

Select the flow control method used by the currently selected
serial line. Choices are:

None(default)

Hardware

Software