Setup – Lexicon RV-8 User Manual

Page 104

Advertising
background image

Setup

Lexicon

3-56

INTERNAL NOISE TEST

Opens the INTERNAL NOISE message shown on the previous page,
which indicates that the internal noise test generates loud calibration
noise signals.

When the INTERNAL NOISE message opens:

Press the

arrow button to open the SPEAKER LEVEL ADJUST

menu shown on the previous page. When the SPEAKER LEVEL
ADJUST menu opens, the internal noise test automatically
begins.

Press the

button to skip the internal noise test.

During the internal noise test, the RV-8 sends calibration noise signals
to each speaker in the order shown on the SPEAKER LEVEL ADJUST
menu. The cursor automatically scrolls through output level param-
eters, highlighting each parameter as the RV-8 sends the calibration
noise signal to the corresponding speaker. The calibration noise
signal is sent to each speaker for about 4 seconds.

Note:

When the internal noise test begins, the RV-8 automatically sets
volume level to +0dB. Avoid adjusting the master volume level while
the test is in progress, to achieve THX reference levels (75dB).

INTERNAL NOISE TEST LEVELS CALIBRATION MANUAL SPEAKERS SETUP

To manually calibrate output levels during the internal noise test:

1. Set the SPL meter to “C” weighting and “SLOW” response.

2. Place the SPL meter at the primary listening position.

3. Press the

or

arrow button to highlight the desired output

level parameter. Then, quickly press the

button to select this

output level parameter. The horizontal bar graph shown on the
previous page will open in the on-screen display and automatic
scrolling will stop.

Note:

During the internal noise test, it is possible to select an output level
parameter just as the cursor is about to automatically scroll to the
next parameter, causing the RV-8 to send the calibration noise
signal to both speakers. If this occurs, reselect the desired speaker.

4. When the horizontal bar graph opens, press the

or

button

to select the output level that achieves a 75dB SPL meter reading
from the primary listening position.

5. Press

to close the parameter. The internal noise test will

continue and automatic scrolling will resume.

6. Repeat steps 2, 3, 4 and 5 until all desired output levels have

been set.

SPEAKERS

SETUP

MANUAL

LEVELS CALIBRATION

INTERNAL NOISE TEST