background image

Diagnostic Error Code

FRU/Action

018-250-XXX PCI Card Services error

1. PCI card

2. Riser card, if installed

3. System board

020-000-XXX PCI Interface Test Passed

No action

020-0XX-XXX PCI Interface error

1. PCI card

2. Riser card, if installed

3. System board

020-195-XXX PCI Test aborted by user

Information only Re-start the test, if necessary

020-196-XXX PCI test halt, error threshold exceeded

1. Press F3 to review the log file

2. Re-start the test to reset the log file

020-197-XXX PCI test warning

1. Make sure the component that is called out is

connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39

2. Re-run test

3. Replace the component that is called out in warning

statement

4. Replace the component under test

020-198-XXX PCI test aborted

1. If a component is called out, make sure it is

connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39

2. Flash the system and re-test. See "Flash update

procedures" on page 467

3. Go to "Undetermined problems" on page 65

020-199-XXX PCI test failed, cause unknown

1. Go to "Undetermined problems" on page 65

2. Flash the system and re-test. See "Flash update

procedures" on page 467

3. Replace component under function test

020-262-XXXPCI system error

1. PCI card

2. Riser card, if installed

3. System board

025-000-XXXIDE interface Test Passed

No action

025-00X-XXX 025-01X-XXX IDE interface failure

1. IDE signal cable

2. Check power supply voltages

3. Reseat IDE signal cable

4. IDE device

5. System board

025-027-XXX IDE interface Configuration/Setup error

1. IDE signal cable

2. Flash the system. See "Flash update procedures" on

page 467

3. Reseat IDE signal cable

4. IDE device

5. System board

Chapter 7 Symptom-to-FRU Index