Diagnostic Error Code

FRU/Action

080-197-XXX Game Port interface test warning

1. Make sure the component that is called out is

connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39

2. Re-run test

3. Replace the component that is called out in warning

statement

4. Replace the component under test

080-198-XXX Game Port interface test aborted

1. If a component is called out, make sure it is

connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39

2. Flash the system and re-test. See "Flash update

procedures" on page 467

3. Go to "Undetermined problems" on page 65

080-199-XXX Game Port interface test failed, cause
unknown

1. See "Undetermined problems" on page 65

2. Flash the system and re-test. See "Flash update

procedures" on page 467

3. Replace component under function test

086-000-XXX Mouse Port interface Test Passed

No action

086-001-XXX Mouse Port interface Presence

1. Mouse

2. System board

086-032-XXX Mouse Port interface Device controller
failure

1. Mouse

2. System board

086-035-XXX Mouse Port interface Reset

1. Mouse

2. System board

086-040-XXX Mouse Port interface IRQ failure

1. Run Setup

2. Mouse

3. System board

086-195-XXX Mouse Port interface Test aborted by user

Information only Re-start the test, if necessary

086-196-XXX Mouse Port interface test halt, error
threshold exceeded

1. Press F3 to review the log file

2. Re-start the test to reset the log file

086-197-XXX Mouse Port interface test warning

1. Make sure the component that is called out is

connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39

2. Re-run test

3. Replace the component that is called out in warning

statement

4. Replace the component under test

086-198-XXX Mouse Port interface test aborted

1. If a component is called out, make sure it is

connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39

2. Flash the system and re-test. See "Flash update

procedures" on page 467

3. Go to "Undetermined problems" on page 65

Chapter 7 Symptom-to-FRU Index