Mounting the MGC-50 on a Rack

The MGC-50 can be mounted in a 19” rack using two mounting plates (Kit
2012A). The side plates are usually mounted when shipped, but if not, follow
the directions below to install the mounted plates on the MGC-50 and then
mount the MGC-50 on the 19” rack.

To install and mount the MGC-50:

1.

Make sure that the MGC-50 power is turned OFF and it is disconnected
from the AC power.

2.

Remove the five nylon plug hole covers from the MGC-50 protective
side covers (using a slotted screwdriver).

3.

Using an Allen wrench (M4), remove the five screws from the MGC-50
side covers.

4.

Remove the MGC-50 side covers from both sides.

5.

To remove the plate from both MGC-50 sides, the side screws have to be
removed. To remove the screws from the left side the main control
module and the power supply must be removed first. These procedures
are described in Chapter 5 of this manual. For detailed procedures, see
Chapter 5, “Replacing the Main Control Module” on page 5-17. For
instructions on how to remove the power supply see Chapter 5,
“Replacing the Power Supply Module for the MGC-50” on page 5-12.

rear

front

remove
screws