12

49 "

(1245)

STALE AIR

TO OUTSIDE

FRESH AIR

TO INSIDE

14 3/4"

(375)

19"

(483)

Por ts

7" (178 mm)

CONDENSATE

DRAINS

BLOWERS

*NOTE: Front clearance of 25 inches (635 mm)
is recommended for ser vicing unit.

MOTOR

FRESH AIR

FROM OUTSIDE

STALE AIR

FROM INSIDE

FILTER

DEFROST

DAMPER

DEFROST AIR

FROM INSIDE

FILTER

Por ts

6" (150 mm)

METAL CLASPS

OPTIONS
99-104

Digital Electronic Timer - 20/40/60 min.

99-109

Air Sentry™ Air Quality Monitor designed to accept
remotely mounted Control Pad

99-250

Ventilation Dehumidistat - Dehumidistat designed to
accept remotely mounted Control Pad.

99-160

Duct Heater w/ Electronic SCR Thermostat, 1 Kw, 7”
(178 mm)

99-161

Duct Heater w/ Electronic SCR Thermostat, 2 Kw, 7”
(178 mm)

99-186

Weatherhoods, Two - 6” (150 mm) c/w 1/4” (6mm)
mesh screen

WARRANTY
Units carry a LIFETIME warranty on the heat recovery core and a

5 year replacement parts warranty.

TI-101-NE

0107

ENGINEERING DATA

THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
The cross-flow heat recovery core transfers heat between the two airstreams.
The two cores are arranged for highly efficient counter current airflow.
MOTORS AND BLOWERS
Each air stream has one centrifugal blower driven by a common PSC motor.
5 speed fan operation. 120 VAC, 1.5 Amps.
FILTERS
Washable air filters in exhaust and supply air streams.
MOUNTING THE HRV
Four threaded inserts at corners of case designed to accept four reinforced
polyester straps that are supplied with the unit.
DEFROST
Damper defrost system.
DEHUMIDISTAT
Adjustable Internal Dehumidistat.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion resis-
tance. Insulated to prevent exterior condensation. Drain connections 2 - 1/2"
(12 mm) OD.
CONTROLS
ControlAir 15 - Standby/ON mode, 20 ON/ 40 OFF mode (each mode has 5
speeds). Control pad can be removed from HRV and remotely mounted.

Weight 106 lbs. (48 kg) Shipping Weight 108 lbs. (49 kg)

All units conform to
CSA and UL standards.

Model 195DCS

DIMENSIONS 195DCS

inches (mm)

*Sensible Efficiency – thermal **Latent Efficiency – moisture
Note: Effectiveness - based on temp. differential between the 2 airstreams
Efficiency – takes into account all power inputs

Performance

(HVI certified)

Net supply air flow in cfm (L/s) against external static pressure

E.S.P

(external static pressure)

[cfm (L/s)]

@ 0.1" (25 Pa)

203 (96)

@ 0.2" (50 Pa)

191 (90)

@ 0.3" (75 Pa)

182 (86)

@ 0.4" (100 Pa)

167 (79)

@ 0.5" (125 Pa)

155 (73)

@ 0.6" (150 Pa)

138 (65)

@ 0.7" (175 Pa)

104 (49)

Max. Temperature Recovery

88%

Sensible Effectiveness
@ 114 cfm (54 L/s)

32°F (0°C)

88%

*Sensible Efficiency
@ 114 cfm (54 L/s)

32°F (0°C)

81%

*Sensible Efficiency
@ 119 cfm (56 L/s)

-13°F (-25°C)

77%

VAC @ 60HZ

120

WATTS / Low speed.

100

WATTS / High speed

173

Amp rating

1.5

1

2

3

4

5

20

40

60

80

100

120

140

160

180

200

220

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

Static Pressure (in w.g.)

Ai

r F

lo

w

(

c

fm

)

5 - High Speed
*4 - Medium High Speed
*3 - Medium Speed
*2 - Medium Low Speed