Troubleshooting guide, Quartz thermo installation guide, Symptom possible cause action – Quartz QZ3111 User Manual

Page 14: Page 14

Advertising
background image

Quartz Thermo installation guide

page 14

Troubleshooting guide

Water output is either

all hot or all cold,

or cold only

Symptom

Possible cause

Action

Reversed inlet supplies

Check that the supplies

correspond with the inlet

markings

Water output is not hot

enough

The temperature of the hot

water cylinder is too low

Water flow through the

appliance is too fast

The cylinder temperature

should be at least 15˚c

hotter than the blend

Check the flow rate

recommendations with

the heater manufacturer

Flow rate is poor and

water temperature is low

Airlock in the water

supply

Check that the pipe work

is laid in accordance with

the correct practices,

paying particular attention

to potential air-traps

Water temperature

regularly swings between

hot and cold

Cold water pressure is

too high

The flow regulator has

not been fitted

If the static water pressure

exceeds 7 bar (100 psi)

install a pressure reducing

valve (PRV) in accordance

with the installation guide

Fit the flow regulator

Poor flow rate

Twisted hose

Debris in shower head

Debris in filters

Debris in cold inlet flow

regulator

Check and clear as

necessary