Warning, Installation – Thomas & Betts 15D User Manual

Page 26

Advertising
background image

Part No. 90-0123-00

Libertycombi.p65 10/26/98

26

DC Wiring

DC wiring is generally very simple, the

positive (+, may be red for identification) and
negative (-, may be black or yellow for
identification) cables from the inverter/charger
terminal posts are connected to the house or
auxiliary battery. Connection to the engine
starter battery is not recommended.

High current will pass through the DC

wiring. All wires must be properly sized and
all connections clean and tight. It is
recommended that the battery cable length
does not exceed 10 feet.

Battery cables should be connected to the

inverter/charger before any connections are
made to the battery. Follow the battery
hardware stackup diagram.

• Remove the negative (-) battery cable

cover from the unit and attach the battery
cable. Tighten the battery terminal bolts to a
torque value between 160 inch-pounds and
180 inch--pounds. Replace the cover for the
negative terminal before removing the cover for
the positive terminal.

INSTALLATION

Ground Fault Circult Interrupters

To conform to NEC regulations, certain

branch circuits must be equipped with a
Ground Fault Circuit Interrupter (GFCI). Please
consult the code or a qualified electrician for
details. Any such branch circuits must be
protected by a brand rated circuit breaker
consistent with the GFCI rating. Underwriters
Laboratories has tested the following GFCI,
and its use is recommended. Receptacle
Type:

Pass & Seymour
Catalog Number 1591
Rated: 15 Amps at 120 Volts AC

Remote Control Wiring

If installing a remote panel, route the

remote cable and connect to the Remote jack
on the front of the unit. Refer to the Remote
Control Panel or Link Owner’s Manual for more
information.

TSC Temperature Sensor

If installing the TSC (Temperature

Sensitive Charging) sensor, connect the ring
terminal end to the positive battery post,
complete the routing of the RJ11 cable (15 feet
supplied) and connect the plug end to the TSC
jack on the front of the unit

Freedom Inverter/Chargers are not protected against DC reverse polarity. Be very careful to connect the
negative and positive cables correctly or damage will result and the warranty will be void.

WARNING

Bolt

Lock Washer

Flat Washer

Battery Cable

Battery Cable
Hardware Stackup
Diagram

CAUTION Improper stackup may result in
excessive heat and damage to the unit.

Inverter/Charger

RJ11 Cable

Battery

Freedom 20D shown.

TSC Jack

Advertising
This manual is related to the following products:

20D, 15, 20