Disassembly: pump, Danger – Viking 823 User Manual

Page 6

Advertising
background image

SECTION TSM

845.1

ISSUE

C

PAGE 6 OF 13

DISASSEMBLY: PUMP

1. See figure 5 or figure 6 on page 5 for name of

parts.

2. Mark the head, casing and bracket before dis-

assembly to insure proper reassembly. The idler pin,

which is offset in pump head, must be positioned

toward and equal distance between port connections

to allow for proper flow of liquid through pump.

3. Unless there appears to be something wrong with the

relief valve (if present), leave assembled and attached

to the pump head. If disassembly is required, refer to

PRESSURE RELIEf VALVES on page 12. Remove

the pump head capscrews (LQ & LS) or the nuts (Q &

QS).

4. Carefully remove the head from the pump. Make

sure the idler does not slide off the idler pin by tilting

the pump head back while removing. Avoid damage

to the head gasket set or O-ring since all gaskets

are required to set end clearance and the O-ring

enhances sealing.

5. Remove the idler and bushing assembly from

idler pin. If the idler bushing needs replacing, see

INSTALLATION Of BUSHINGS on page 9.
Disassembly and inspection of the pump in this

manner is generally sufficient for routine evaluation

of the pump’s condition. If the idler pin and bushing

are original parts and in good condition, usually the

rest of the pump is also in good condition.

fIGURE 7

EXPLODED VIEW – D SERIES COUPLING

ITEM

DESCRIPTION

ITEM

DESCRIPTION

ITEM

DESCRIPTION

1

Locknut

9

Jack Screws

17

Outer Magnet Assembly

2

Lockwasher

10

Set Screws

18

Bracket

3

Endcap

11

Insert

19

Temperature Monitor (Optional)

4

Lip Seals

12

Capscrews, Bearing Housing

20

Pipe Plug

5

Bearing Spacer, Outer

13

Grease Fitting

21

Capscrews for Canister

6

Tapered Roller Bearing, Outer

14

Bearing Housing

22

Canister

7

Bearing Spacer, Inner

15

Gasket, Bearing Housing

23

Washer

8

Tapered Roller Bearing, Inner

16

Key

24

Inner Magnet Assembly

DANGER !

Before opening any Viking pump liquid

chamber (pumping chamber, reservoir, relief

valve adjusting cap fitting etc.) Be sure:
1. That any pressure in the chamber has

been completely vented through suction

or discharge lines or other appropriate

openings or connections.

2. That the driving means (motor, turbine,

engine, etc.) has been “locked out” or

made non-operational so that it cannot

be started while work is being done on

pump.

3. That you know what liquid the pump

has been handling and the precautions

necessary to safely handle the liquid.

Obtain a material safety data sheet

(MSDS) for the liquid to be sure these

precautions are understood.

failure to follow above listed precautionary

measures may result in serious injury or

death.

Advertising