4. To facilitate disassembly, it may be necessary to slide

a block of wood under the pump casing or clamp pump

foot as shown, since the pump alone will not balance on

foot. See

figure 11. Remove the (4) 0.50” capscrews

securing the pump to the coupling bracket. After parting

the bracket slightly, it will have a tendency to be drawn

to one side due to the inner magnet. Pull the coupling

bracket completely away.

5. There will probably be some liquid left in the canister so

take the necessary safety precautions. The canister drain

is located behind the mounting flange and near the

underside. Removing plug will drain most of the canister.

Once the liquid has drained, replace the plugs.

3. Set the outer assembly with magnets down on a clean,

flat surface (preferably not steel) to keep from rolling

around. Remove temperature probe (if present).

fIGURE 11

fIGURE 12

fIGURE 13

fIGURE 14

7. Insert a brass bar through a port between two rotor teeth

and loosen the capscrew holding the inner magnet onto

the shaft. See

figure 13. The 0.437” capscrew has right

hand threads therefore turn it counterclockwise. THE

INNER MAGNET HAS A VERY STRONG MAGNETIC

FIELD AND IS MOST DANGEROUS IN THE UN-

ASSEMBLED CONDITION. THE MAGNET IS QUITE

HEAVY AND WILL BE DRAWN TO ANY FERROUS

OBJECT OR SURFACE CAUSING POTENTIAL

PINCHING. BEWARE OF THE CAUTIONS LISTED

ON (PAGE 3). USE EXTREME CARE SLIDING THE

MAGNET OFF OF THE PUMP SHAFT. SET THE

MAGNET DOWN ON EITHER END AWAY FROM ALL

OTHER OBJECTS. See figure 14. Remove the key

and the external snap ring (LQ & LS) and then finish

disassembly of the pump.

6. Remove the (8) 0.375” Allen head capscrews holding the

canister in place then slide the canister off. See

figure

12.