TROUBLESHOOTING

Note:

All troubleshooting items are listed in order of operation.

WARNING: Turn off and unplug heater and let cool before servic-

ing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean

ODS/pilot. This can damage ODS/pilot unit.

POSSIBLE CAUSE

1. Ignitor electrode positioned

wrong

2. Ignitor electrode broken
3. Ignitor electrode not con-

nected to ignitor cable

4. Ignitor cable pinched or wet

5. Broken ignitor cable
6. Bad ignitor
7. Battery not installed, battery

power low, or battery not in-
stalled correctly (electronic ig-
nition models only)

1. Gas supply turned off or equip-

ment shutoff valve closed

2. Control knob not fully pressed

in while pressing ignitor but-
ton (non-thermostat models
only)
Thermostat control knob not
fully pressed in while pressing
ignitor button (thermostat
models only)

3. Air in gas lines when installed

4. Depleted gas supply (propane/

LP gas)

5. ODS/pilot is clogged

6. Gas regulator setting is not

correct

7. Thermostat control knob is not

in pilot position (thermostat
models only)

REMEDY

1. Replace pilot assembly

2. Replace pilot assembly
3. Reconnect ignitor cable

4. Free ignitor cable if pinched

by any metal or tubing. Keep
ignitor cable dry

5. Replace ignitor cable
6. Replace ignitor
7. Install new alkaline battery in

electronic ignitor. Verify bat-
tery is installed correctly

1. Turn on gas supply or open

equipment shutoff valve

2. Turn to PILOT/IGN position.

Fully press in control knob
while pressing ignitor button
(non-thermostat models only)
Fully press in thermostat con-
trol knob while pressing igni-
tor button (thermostat models
only)

3. Continue holding down con-

trol knob. Repeat igniting op-
eration until air is removed

4. Contact local propane/LP gas

company

5. Clean ODS/pilot (see Cleaning

and Maintenance, page 19) or
replace ODS/pilot assembly

6. Replace gas regulator

7. Turn thermostat control knob

to pilot position

OBSERVED PROBLEM

When ignitor button is pressed
in, there is no spark at ODS/
pilot

When ignitor button is pressed
in, there is a spark at ODS/Pilot
but no ignition

Advertising