Configuring remote control using rs-485, Rs-485 communication cable with rj-45 to db-9, Configuring remote control using rs-485 –7 – Xantrex Technology XTR 850 Watt User Manual

Page 129: Table 5-5, Db-9 pinouts –7, Table 5-6, Rj-45 plug pinouts –7

Advertising
background image

Hardware and Connection Setup

975-0200-01-01

5-7

5

Configuring Remote Control Using RS-485

RS-485 Communication Cable with RJ-45 to DB-9

Communication control cable with DB-9 pinout (female) on the PC side
(see Figure 5-2) and RJ-45 shielded connector on the power supply.
The cable length should be 9.84 feet (3 m) or longer.

Table 5-5 DB-9 Pinouts

Pin

Name

Description

1

GND

Ground

2, 3

NC

No connection

4

RXD+

Receive data

Twisted
pair

5

RXD–

Receive data

6, 7

NC

No connection

8

TXD+

Transmit data

Twisted
pair

9

TXD–

Transmit data

Table 5-6 RJ-45 Plug Pinouts

Pin

Name

Description

1, 2

NC

No connection

3

TXD+

Transmit data

Twisted
pair

4

TXD–

Transmit data

5

RXD+

Receive data

Twisted
pair

6

RXD–

Receive data

7

GND

Ground

8

NC

No connection

Advertising