Calibration and Troubleshooting
6-4
975-0200-01-01
Step 2: Offset Calibration
Adjust the offset so that the real and ideal lines intersect at a programmed
value of 10%.
Step 3: Recalibrate Gain
Repeat Step 1 for best results.
Figure 6-3 Calibration: Step 2 Offset Calibration
Figure 6-4 Calibration: Step 3 Recalibrate Gain