9.2.3.7.

CHANGE_CODE (only SLE 4442) (*)

To write the specified data as new secret code in the card.

The current secret code must have been presented to the card with the PRESENT_CODE command
prior to the execution of this command!

Command format

Instruction

Code

Data length

Data

CODE

93

H

03

H


CODE

The three bytes new secret code (PIN)


Response data format

No

response

data


Note (*) – SAM Reader does not support for memory cards

9.2.4.

Siemens SLE 4418/4428 intelligent 1K Byte Memory Card (*)

9.2.4.1.

RESET (*)

This command powers up the card inserted in the card reader and performs a card reset.

If the card is powered up when the command is being issued, only a reset of the card is carried out,
the power supply to the card is not switched off.

Command format

Instruc

tion

Code

Data

length

80

H

00

H

Response data format

ATR

ATR

Four bytes Answer-To-Reset read from the card.

The ATR bytes are read from the card with LSB first, i.e., the first bit read from the card is
the LSB of the first ATR byte.

9.2.4.2.

POWER_OFF (*)

This command powers off the card inserted in the card reader.