3-17

Chapter 3

Tweakers’ Paradise

The subitems in this menu allow you to set the CPU ratio and features.

BCLK Tuning
VCCIN Shadow Voltage [Auto]
Pseudo Voltage for VCCIN. Configuration options: [Auto] [0.800] – [2.440V]
Termination Anti-Aliasing [Auto]
Termination Anti-Aliasing can be enabled to smooth out the change of the PLL

Termination Voltage, which may sometimes help to yield a better O.C. result..

Configuration options: [Auto] [Disabled] [Enabled]
Initial PLL Termination Voltage [Auto]
Initial Voltage at which CPU BCLKs are terminated. Maintaining a level close to CPU

Input Voltage will help BCLK Overclock.

Configuration options: [Auto] [0.0000] - [3.0000]
PLL Termination Reset Voltage [Auto]
PLL Termination Reset Voltage. Configuration options: [Auto] [0.0000] - [3.0000]
Eventual PLL Termination Voltage [Auto]
Eventual PLL Termination Voltage. Configuration options: [Auto] [0.0000] - [3.0000]

[Auto] [0.0000] - [3.0000]

ICC Ringback Canceller [Auto]
ICC Ringback Canceller can be used to control the noise level at the Integrated Clock

Controller.

[Enable] to allow better High DMI Frequency O.C.

[Disable] to allow better Low DMI Frequency O.C.
Clock Crossing VBoot [Auto]
The instantaneous voltage value when the rising edge of BCLK DN is equal to the

falling edge of the BCLK DP. Configuration options: [Auto] [0.1000] - [1.9000]
Clock Crossing Reset Voltage [Auto]
The instantaneous voltage value when the rising edge of BCLK DN is equal to the

falling edge of the BCLK DP. Configuration options: [Auto] [0.1000] - [1.9000]
Clock Crossing Voltage [Auto]
The instantaneous voltage value when the rising edge of BCLK DN is equal to the

falling edge of the BCLK DP. Configuration options: [Auto] [0.1000] - [1.9000]
DMI Gen 2 [Auto]
Allows you to enable or disable DMI Gen 2. Auto means Enabled. Configuration

options: [Auto] [Enabled] [Disabled]
DMI De-emphasis Control [-6 dB]
Configure De-emphasis control on DMI. Configuration options: [-6 dB] [-3.5 db]