OPERATING INSTRUCTIONS

VOLTAGE MEASUREMENT

1. Connect red test lead to “VΩ” jack, black lead to “COM” jack.
2. Set RANGE switch to desired VOLTAGE position, if the voltage

to be measured is not known beforehand, set switch to the
highest range and reduce it until satisfactory reading is

obtained.

3. Connect test leads to device or circuit being measured.

4. Turn on power of the device or circuit being measured voltage

value will appear on Digital Display along with the voltage

polarity.

Please note:

In small range, the meter may display an unstable reading

when the test leads have not been connected to the load to be
measured. It is normal and will not affect the measurements.

When the meter shows the over range symbol “1”, a higher

range must to be selected.

To avoid damage to the meter, don’t measure a voltage which

exceeds 600Vdc (for DC voltage measurement) or 600Vac (for

AC voltage measurement).


CURRENT MEASUREMENT


1. For reading less than 200mA connect red lead to “mA” and

black lead to “COM” (for measurements between 200mA and
10A, connect red lead to “10A”) ensure jacks are fully

depressed.