Hand Held Transmitter

Rio Rancho, NM

5

A mic capsule is

threaded onto the body

of the transmitter in the

direction shown.

Do not overtighten it.

The lower housing opens by rotating

it in the direction shown. After the

threads are disengaged, pull the

housing downward until it engages

the detent that holds it open.

The threaded interface is a 1.25”

opening with 28 threads per inch

and three contact rings

Mic Capsules:

Lectrosonics offers two types of capsules. The HHC is

the standard capsule and the HHVMC is the Variable

Mic Capsule which includes adjustments for Bass,

Midrange and Treble.

HHC Lectrosonics

cardioid electret

HHVMC Lectrosonics cardioid

electret with VariMic preamp

Along with these two models from Lectrosonics, a

variety of different capsules with Shure

®*

& EV

®*

type

threads and electrical interface will work from different

manufacturers. This gives you the flexibility to choose

your capsule to use with the HH wireless transmitter.
A list of compatible capsules is on the website at:
http://www.lectrosonics.com/images/PDFs/hh_

compatible_microphone_capsules.pdf

Capsule Installation

Capsules are attached with a right-hand thread.
To remove the windscreen from the mic capsule,

line up the blue wrench (included with the capsule

head) with the flat notches on the lower threaded area

of the mic capsule.

Do not touch the contacts between the mic capsule

and transmitter body. When necessary, the contacts

can be cleaned with a cotton swab and alcohol.

*All product names are trademarks of their respective