Part 3 Maintenance

(2) DeviceNet

LED name

Displayed

color

Condition

Action

Unlit

Offline/no power

Communication with the master is not yet

established. Check the DeviceNet

communication power supply (+24 V),

power supply of the gateway unit,

communication cable, etc.

Green

The unit is online and connection has been

established (normal).

-

Blinking

green

(1 Hz)

The unit is online but connection has not

been established yet.

The occupancy information or station

number of the master is inconsistent with

the corresponding information of the

gateway unit. Review these settings.

Orange

Fatal error

Replace the gateway unit.

Blinking

orange

(1 Hz)

Connection timeout

The master cannot be recognized.

Check the condition of the master and

communication cable.

STATUS-1

Alternating

red/green

Self-diagnosis is being performed.

-

Unlit

No power

Check the power supply of the gateway

unit.

Green

Normal operation (normal)

-

Blinking

green (1 Hz)

Configuration information is not available or

incomplete.

Check the configuration settings again.

Orange

Irrecoverable failure

Replace the gateway unit.

Blinking

orange (1 Hz)

Recoverable failure

Reconnect the power.

STATUS-0

Alternating

orange/green

Self-diagnosis is being performed.

-

(3) Profibus

LED name

Displayed

color

Condition

Action

Unlit

Offline/no power

Communication with the master is not yet

established. Check the station number

setting, power supply, communication

cable, etc.

Green

Online (data exchanged) (normal)

-

Blinking

green

Online (data cleared)

A clear command is being received from

the master following a network error. Reset

the master.

Orange

Parameter error

Check the network parameters again.

STATUS-1

Blinking

orange

Configuration error

The occupancy information of the master is

different from that of the gateway unit. The

coverage of the gateway unit may be

smaller. Check the settings again.

Unlit

No power, or initialization not yet

performed

Check the power supply.

Green

Initialization has completed (normal).

-

Blinking

green

Initialization has completed (diagnosis

event triggered).

Reconnect the power.

STATUS-0

Orange

Exceptional error

Replace the gateway unit.