LOGIC

5-30

Logic 11b: The logic for apparatus with NO/NC contact inputs

Overview (Logic 11b)

This logic function is for using dual channel NO/NC contact devices as safety protective measures
for semiconductor manufacturing machines and food packaging machinery. Safety outputs perform
as dual channel outputs.
This logic has 2 dual inputs for direct opening inputs and 4 dual channel inputs for NO/NC contact
devices.

Safety input 1

Safety input 6

Safety input 2

Safety input 3

Safety output 1
or
Safety output 2

Safety input 4

Safety input 5

System runs

Safety
output 1

Safety
output 2

Logic 11b

Emergency
stop switch

Safety switch

Non-contact
Interlock switch

Operation example (Logic 11b)

Safety input 1

Safety input 6

Safety input 2

Safety input 3

Safety output 1
or
Safety output 2

Safety input 4

Safety input 5

System stops

Press!

Open!