Serial Interface

„ RS-232C and RS-422/485 Types (GP4105/GP4106)

Included COM I/F connector

(9-pin, 2-piece terminal block)

• For instructions on how to connect to other devices, always refer to the “GP-Pro EX

Device/PLC Connection Manual”.

• The serial interface of the RS-232C and RS-422/485 types is not isolated. Always

connect the SG (Signal Ground) of the GP unit to the connected device, especially if

the connected device is also not isolated. Failure to do so may damage the RS-

232C/RS-422/RS-485 circuit.

• An SG (Signal Ground) and FG (Frame Ground) are connected internally in the RS-

232C and RS-422/485 types. When connecting an external device to the GP using

the SG terminal, be sure to check that no short-circuit loop is created when you

setup the system.

RS-232C type

RS-422/485 type

Label

Signal

Name

Direction

Meaning

Label

Signal

Name

Direction

Meaning

CI

CI(RI)

Input

Called status
display

CSB

CSB

Input

Send
Possible B (-)

CD

CD

Input

Carrier Detect

CSA

CSA

Input

Send
Possible A (+)

CS

CS(CTS)

Input

Send
Possible

ERB

ERB

Output

Data Terminal
Ready B (-)

RS

RS(RTS)

Output

Request to
Send

ERA

ERA

Output

Data Terminal
Ready A (+)

SG

SG

Signal
Ground

SG

SG

Signal
Ground

DR

DR(DSR)

Input

Data Set
Ready

RDB

RDB

Input

Receive Data
B (-)

ER

ER(DTR)

Output

Data Terminal
Ready

RDA

RDA

Input

Receive Data
A (+)

RD

RD(RXD)

Input

Receive Data

SDB

SDB

Output

Send Data B
(-)

SD

SD(TXD)

Output

Send Data

SDA

SDA

Output

Send Data A
(+)

A terminating resistor can be inserted using the DIP Switch (4-bit) on the rear of the RS-422/485

type. Factory default settings are all set to “OFF” (no terminating resistor). Check the terminating

resistor required for connection to the connected device (PLC) and install if necessary. For

detailed information, refer to the GP-Pro EX Device/PLC Connection Manual.