6.

What To Do if a Malfunction Occurs

6.1

Shut the main power OFF and restart the humidifi er to see if the error code disappears.

6.2

If you see a water leak, follow the water supply tube and close the valve installed on the water pipe

located near the humidifi er.

6.3

Please refer to the error code table to identify the possible cause of the malfunction and the actions that

you can take.

6.4

Should the problem persist, please call your service company. They are the best qualifi ed to help you

quickly. Describe the problem to them and mention the error code you observed on the front panel. They may
help you solve the problem over the phone. If needed, they will fi x the problem themselves or call our technical
service.

6.5

Should you attempt to look at the unit yourself, please apply all appropriate safety measures. - Shut the

main power OFF and wait for the unit to cool before you open it.

7.

Description of Error Codes

Number of

fl ashes of the

red light

Error Description

Humidifi er Status

Actions to be Taken

by the Owner

Reset

OFF

No error

The humidifi er is working fi ne

None

Continuous

ON

There is water in the
pan under the tank.

Risk of overfl ow. Humidifi er stops
itself.

Turn the main power OFF, then
- Open the unit and check for leaks
- Check the drain tube
- Close the supply valve and call for
service

Automatic Reset when
switching main power ON
again.

1

Problem with the water
level sensors inside the
unit.

Internal problem - Humidifi er cannot
read the water level properly and
stops itself.

Turn the main power OFF, then call
your service company

Automatic Reset when
switching main power ON
again.

3

Inadequate water
supply.

Humidifi er cannot fi ll properly and
stops itself - Heating elements and
supply valve are switched off.

Turn the main power OFF, then
- Check the water supply circuit
- Check if the water supply valve is
open.
- Call your service company

Automatic Reset when
switching main power ON
again.

4

Inadequate drainage.

Humidifi er cannot drain properly -
Risk of overfl ow - the unit stops itself.

Turn the main power OFF, then
- Close the supply valve
- Call your service company

Automatic Reset when
switching main power ON
again.

5

Fan not running.

Humidifi er stops itself.

Turn the main power OFF, then
- Call your service company

Automatic Reset when
error conditions disappear.

6

Temperature inside the
tank exceeded the high
temperature limit and
the safety switch has
tripped.

This is a very serious condition.
The humidifi er stops itself and cannot
restart without service.

Turn the main power OFF, then
- Call your service company

Only the service company
can reset the unit after
checking all functions.