9.4 FAN SETTINGS

Select which Fan you would like to view
or make changes to.


9.4.1 Pulses Per Rev


This is the number of pulses produced
by the fan sensor in one revolution. The
pulse setting is equal to the number of
targets presented to the fan sensor in
one revolution.

9.4.2 Low Alarm Point


The Low Alarm Limit is set by the user
for low rpm notification. Default is 1500
RPM

9.4.3 High Alarm Point

The High Alarm Limit is set by the user
for high rpm notification. Default is 5500
RPM.

**Fan RPM above the High Alarm Point
or Below the Low Alarm Point will cause
an alarm condition that cannot be acknowledged.

9.5 BIN SETTINGS

The Bin Settings Menu gives you the
ability to enable or disable the bin
alarms.
 

 
 
 
 
 
 
 
 
 