(1) The receiver will shut down very shortly and will not restart
until the battery temperature comes back within the
permitted temperature range. Fast blinking will also occur if
the same problem is detected while you are attempting to
power up the receiver (will stop when you release the Power
button).

LED

indications

Meaning

Only Battery A inserted

Battery temperature outside of permitted range (1).

Only Battery B inserted

Battery temperature outside of permitted range (1).

Batteries A and B inserted

Battery temperature outside of permitted temperature range.
Use of any of the two batteries is prohibited (no discharging
allowed). (1)

AC/DC Adapter Connected to the Receiver, Battery A Inserted

Battery temperature outside of permitted temperature range.
Battery A charging suspended.

AC/DC Power Block Connected to Receiver, Battery B Inserted

Battery temperature outside of permitted temperature range.
Battery B charging suspended.

AC/DC Power Block Connected to Receiver, Batteries A and B Inserted

Battery temperature outside of permitted temperature range.
Battery charging suspended, whichever was being charged.