In-Situ TROLL 9500 Operators Manual User Manual

Page 18

Advertising
background image

11

TROLL 9500 Operator’s Manual

0095110 rev. 007 01/09

pH

Type

Glass sensing bulb, single-junction
electrode, replaceable ceramic junction,
refillable reference electrolyte

Range

0 to 12 pH units

Pressure Rating

350 psi 246 m, 807 ft

/PERATING

½#

Accuracy

± 0.1 pH unit

Resolution

0.01 pH unit

pH/ORP

Type

Glass sensing bulb, platinum wire, single-
junction electrode, replaceable ceramic
junction, refillable reference electrolyte

Range

± 1400 mV, 0 to 12 pH

Pressure Rating

350 psi 246 m, 807 ft

/PERATING

½#

Accuracy

± 4 mV, ± 0.1 pH unit

Resolution

1 mV, 0.01 pH unit

Dissolved Oxygen (polarographic)
Type

Clark

polarographic

Range

0 to 20 mg/L, 0 to 200% saturation

Pressure Rating

350 psi (246 m, 807 ft); submersion &
retrieval at up to 4 ft per second

/PERATING

½#

Accuracy

± 0.2 mg/L

Resolution

0.01

mg/L

Extended Sensors

Dissolved Oxygen (optical, RDO)

4YPE

/PTICAL

Range

0 to 20 mg/L, 0 to 450% saturation

Pressure Rating

300 psi

/PERATING

½#

Accuracy

± 0.1 mg/L @ 0-8 mg/L

± 0.2 mg/L @ 8-20 mg/L

Resolution

0.01

mg/L

SECTION 2: COMPONENTS & FEATURES

Ammonium (NH

4

+

)

Type

PVC membrane sensing element, double
junction Ag/AgCl reference half-cell,
reference electrolyte gel

Range

0.14 to 14,000 ppm N (0.1 to 18,000 ppm
NH

4

+

)

Pressure Rating

20 psi (14 m, 46 ft)

/PERATING

½#

Accuracy

±

10%

Resolution

0.01

ppm

Chloride (Cl

)

Type

Solid-state sensing electrode, double
junction Ag/AgCl reference half-cell,
reference electrolyte gel

Range

0.35 to 35,500 ppm Cl (2 to 35,000 ppm
Cl

)

Pressure Rating

100 psi (70 m, 231 ft)

/PERATING

½#

Accuracy

±

15%

Resolution

0.01

ppm

Nitrate (NO

3

)

Type

PVC membrane sensing element, double
junction Ag/AgCl reference half-cell,
reference electrolyte gel

Range

0.14 to 14,000 ppm N (0.4 to 62,000 ppm
NO

3

)

Pressure Rating

20 psi (14 m, 46 ft)

/PERATING

½#

Accuracy

± 10%

Resolution

0.01

ppm

Typical Battery Life @ 20°C

Battery type
Installed sensors

Sample Interval

60 min.

15 min.

2 alkaline D-cells
P

ressure, temperature, baro, pH/ORP, conductivity, polarographic (Clark) D.O.

All of the above plus

turbidity

All of the above plus

turbidity & wiper

Pressure, temp., baro, pH/ORP, conductivity, RDO, turbidity


76 days
75 days
63 days


73 days
70 days
52 days
125 days

2 lithium D-cells
P

ressure, temperature, baro, pH/ORP, conductivity, RDO, turbidity, no wiper


270 days