Obtaining the update (flash) recommendation, All components, Syntax – HP StoreAll Storage User Manual

Page 24: Description

Advertising
background image

Example 8 Discover the active firmware version of a set of components for the 8800 platform

# hpsp_fmt -d -c iLO4, Enclosure_IO_Mod, PCIeNIC, SERVER_HDD
Based on the configuration, FW discovery may take 15 minutes.
<<< Completed >>>

Obtaining the update (flash) recommendation

Syntax

--flashrec

-fr

Description

The output of the --flashrec command includes the recommended action and the severity of
the recommended action. The update recommendation action can be one of the following:

UPGRADE: The active firmware version of the component is lower than the qualified version
and should be upgraded.

DOWNGRADE: The active firmware version of the component is higher than the qualified
version and should be downgraded.

NONE: The active firmware version of the component is equal to the qualified version. No
action is needed unless you want to force a rewrite of the firmware in the case of the current
firmware being corrupt.

The severity of the recommended action can be one of the following:

MANDATORY: It is critical to update the firmware for optimal performance and system stability.

RECOMMENDED: It is optional to update the firmware from a functionality standpoint. However,
it is highly recommended to update the firmware for system stability.

The output also contains information about the reboot requirement of a component for a successful
firmware update, where necessary.

A verbose report includes additional information such as approximate flash duration, dependent
components, and so on.

All components

To get the flash firmware recommendation for all components, run the following command:

# hpsp_fmt -fr all

24

StoreAll 8800 and 8200 FMT command reference and examples

Advertising