All server components – HP StoreAll Storage User Manual

Page 70

Advertising
background image

<<< Succeeded >>>

--------------------------------------------------------------------------------
Device :Smart_Array_Ctlr
Status :Success (Reboot Pending)
Code :0x1001
CONDITIONAL_SUCCESS :Flash succeeded for HP Embedded Smart Array
Controller using CP017183.scexe. The system must
be restarted to complete the operation.
Reboot Required :Yes
Coordinated Reboot Required :No
--------------------------------------------------------------------------------

SUMMARY:
--------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
--------------------------------------------------------------------------------
Smart_Array_Ctlr HP Embedded Smart Array Yes Success (Reboot Pending)
Controller

--------------------------------------------------------------------------------

At this stage, you can optionally reboot the server to activate the updated firmware or wait for
other firmware updates, if any, and perform a reboot once for them all.

All server components

Example 66 Firmware update of all server components on 9320/9300 platforms

# hpsp_fmt –f server
Please read through the following WARNING messages before continuing with the updates:
***WARNING***
- To avoid spurious failure, ensure that high availability (if present), is disabled for this node
- Ensure that all data services including file-system services are stopped
- Do not cycle power or restart devices during the firmware update.

Please confirm you have read all the above warning messages and taken necessary actions (Y/N)?y

Do you want to proceed (Y/N)?y

Flashing ILO4: Based on the configuration, it may take 10 minutes.
<<< Succeeded >>>
Flashing BIOS: Based on the configuration, it may take 5 minutes.
<<< Succeeded >>>
Flashing Power_Mgmt_Ctlr: Based on the configuration, it may take 5 minutes.
<<< Not attempted >>>
Flashing PCIeNIC: Based on the configuration, it may take 10 minutes.
<<< Not attempted >>>
Flashing NIC: Based on the configuration, it may take 10 minutes.
<<< Not attempted >>>
Flashing Storage_Ctlr: Based on the configuration, it may take 10 minutes.
<<< Not attempted >>>
Flashing Storage_Expander: Based on the configuration, it may take 30 minutes.
<<< Not attempted >>>

--------------------------------------------------------------------------------
Device :ILO4
Status :Success
Code :0x1000
SUCCESS :Flash succeeded for Integrated Lights-Out (iLO) 4
using iLO4_FW_LNXSC_122-CP019885.scexe
Reboot Required :No
Coordinated Reboot Required :No
--------------------------------------------------------------------------------
Device :BIOS
Status :Success (Reboot Pending)
Code :0x1001
CONDITIONAL_SUCCESS :Flash succeeded for BIOS using CP018654.scexe.
The system must be restarted to complete the
operation.
Reboot Required :Yes
Coordinated Reboot Required :No
-------------------------------------------------------------------------------
Device :Power_Mgmt_Ctlr
Status :Flash Not Attempted

70

StoreAll 9320 and 9300 FMT command reference and examples

Advertising