Environmental requirements

To ensure proper operation, the switch must not be subjected to environmental conditions beyond
those for which it was tested. The ranges specified in

Table 20

list the acceptable environment for

both operating and nonoperating conditions.

Table 20 Environmental requirements

Acceptable range during non-oper-
ation

Acceptable range during operation

Condition

-40°C to 70°C with maximum rate of
change of 20 C /hr

104°F/40 °C at sea level, derated 1 C
per 1000 ft above sea level

Ambient temperat-
ure

50% to 80% relative humidity, non-
condensing

5% to 90% relative humidity, non-con-
densing

Humidity

0 to 40,000 ft (12 km) above sea level

0 to 10,000 ft (3 km) above sea level

Altitude

140 G, 2mS,

40 G, 2mS duration

Shock

2.0 G, 5–500 Hz

0.5 G, 10–500 Hz

Vibration

None required

47 cubic ft/minute

Airflow

Supported SFPs

Do not use unsupported SFPs. They may not fit correctly and may void your warranty. Any port with
an unsupported SFP will automatically be disabled by switch firmware, leaving the port non-operational.
See

Supported SFP transceiver options

, page 17 for a list of supported SFPs.

For a complete list of supported devices, refer to the latest version of the HP StorageWorks SAN
design reference guide
at the HP website:

nl

http://h18000.www1.hp.com/products/storageworks/san/documentation.html

.

Supported HBAs

For a list of HBAs that have been tested and are known to work with the SAN switches, refer to the
latest version of the HP StorageWorks SAN design reference guide at the HP website:

nl

http://h18000.www1.hp.com/products/storageworks/san/documentation.html

.