PRODUCT DIMENSIONS AND CLEARANCES FOR 48” MODELS

Design Information

27-1/2” to

Front of

Bullnose

8-1/2”

Height

22-3/4” Min.

2-1/2”

8”

7/8”

Universal Utility Locations

2”

17”

16”

Locate gas

inlet on back

wall or on

floor 2” from

back wall.

12” Minimum

Each Side

46-1/4”

48” Min. to

Combustibles

12” Minimum to

Combustibles or 0”

to non-combustible

material above the

cooking surface

0”

Clearance

* The opening between a 4” high

backsplash must be 48” to allow the

rangetop to slide back against the wall.

13” Max.

18” Min.

48” Minimum

to Combustibles

12” Minimum to

Adjacent Wall

47-7/8

Width

WARNING:

Installations without a hood

require 48” minimum to combustibles

above the rangetop. A custom hood

installation with exposed horizontal

combustible surfaces must have

an Auto-On feature. Refer to hood

installation instructions for specific

hood clearances.
The surface of the entire back wall

above the countertop and below

the hood must be covered with

a non-combustible material such

as metal, ceramic tile, brick, marble

or other stone.

*48”

Non-

combustible

material

48”

ADDITIONAL CLEARANCES:

Allow 12” minimum clearance to an

adjacent wall on each side.
Working areas adjacent to the rangetop

should have 18” minimum clearance

between countertop and the bottom of

the wall cabinet.
For island installation, maintain 2-1/2

in. minimum from cutout to back edge

of countertop and 3 in. minimum from

cutout to side edges of countertop (see

top view).

Back

3” Min.

Island

Cutout

Top View

3” Min.

2-1/2” Min.