PRODUCT DIMENSIONS AND CLEARANCES FOR 36” MODELS

Design Information

35-7/8

Width

8-1/2”

Height

5

Universal Utility Locations

2”

17”

16”

Locate gas

inlet on back

wall or on

floor 2” from

back wall.

22-3/4” Min.

2-1/2”

8”

1/2”

12” Minimum

Each Side

35”

* The opening between a 4” high

backsplash must be 36” to allow

the rangetop to slide back against

the wall.

13” Max.

18” Min.

48” Minimum

to Combustibles

12” Minimum to

Adjacent Wall

WARNING:

Installations without a hood

require 48” minimum to combustibles

above the rangetop. A custom hood

installation with exposed horizontal

combustible surfaces must have

an Auto-On feature. Refer to hood

installation instructions for specific

hood clearances.
The surface of the entire back wall

above the countertop and below the

hood must be covered with a non-

combustible material such as metal,

ceramic tile, brick, marble or other

stone.

*36”

Non-

combustible

material

27-1/2” to

Front of

Bullnose

48” Min. to

Combustibles

0”

Clearance

12” Minimum to

Combustibles or 0”

to non-combustible

material above the

cooking surface

36”

ADDITIONAL CLEARANCES:

Allow 12” minimum clearance to an

adjacent wall on each side.
Working areas adjacent to the rangetop

should have 18” minimum clearance

between countertop and the bottom of

the wall cabinet.
For island installation, maintain 2-1/2

in. minimum from cutout to back edge

of countertop and 3 in. minimum from

cutout to side edges of countertop (see

top view).

Back

3” Min.

Island

Cutout

Top View

3” Min.

2-1/2” Min.