Fd12p, Table 17, The mitras polling command is the following – Vaisala FD12P User Manual

Page 67

Advertising
background image

Chapter 4 _________________________________________________________________ Operation

VAISALA ________________________________________________________________________ 67

The status bits emulate the MITRAS status as shown in Table 16 and
Table 17 below.

Table 16

Transmitter Status Correspondence between
MITRAS and FD12P

BIT

MITRAS

FD12P

0

MEAS MODE

ON

1

ECON MODE

OFF

2

OPTICAL SURFACE

TRB warning or alarm

3

POWER SUPPLY

VBB (power supply)

4

HEATING

VH (lens heater current)

5

FLASH LAMP

LEDI (LED intensity control)

6

BL METER

BL meter interface (DRI21)
connected

7

MEASUREM. LOOP SIGNAL

-

Table 17

Receiver Status Correspondence between
MITRAS and FD12P

BIT

MITRAS

FD12P

0

MEAS MODE

ON

1

SPARE

2

OPTICAL SURFACE

REC. BACKSCATTER
warning or alarm

3

POWER SUPPLY

±15 V status

4

HEATING
OK = OFF

5

CALIBRATION

AMBL

6

TEST
OK = OFF

7

SPARE

The MITRAS polling command is the following:

P<sp><ID><cr><lf>