background image

If the power cord for the appliance becomes damaged, this

must be replaced with a special connecting cable that can be

obtained from the manufacturer or the manufacturer's customer

service department.

Appliance measurements (fig. 1)
Preparing the kitchen units (fig. 2)

The fitted unit must be heat-resistant up to 90 °C. The stability of

the fitted unit must also be guaranteed after the cut-out work.
Make the cut-out in accordance with the installation drawing.

The cut surface must be at a 90° angle to the work surface.
After making the cut-outs, remove any shavings. Seal any cut

surfaces to make them heat-resistant.
Ensure that there is a minimum clearance of at least 10 mm

from the underside of the appliance to the unit parts.
The work surface must be reinforced if the gap between the

appliance and the wall is less than 30 mm, or the gap between

the appliance and the hob is less than 50 mm. Otherwise there

is not enough stability. The reinforcing material used must be

heat and moisture resistant.
Notes

The work surface in which the appliance is installed must have

a load-bearing capacity of approximately 60 kg.

Only check the evenness of the appliance after fitting it in the

installation opening.

Fitting the appliance

1.

Slide the appliance into the cut-out of the work surface from

above. (Fig. 3a).

2.

Insert the appliance evenly in the cut-out. From above, push it

down firmly into the cut-out.
Notes

The appliance must be seated securely in the cut-out and

must not move (e.g. during cleaning). If the width of the cut-

out is at the upper end of the tolerance range, secure

battens to the sides of the cut-out, if required.

Remove both of the plastic parts from the left and right of

the cover (picture 3a).

3.

Level the appliance in the cupboard. Ensure that the frame for

the appliance plan lays flat on the work surface. Secure the

mounting bracket to the appliance and the base of the

unit (fig. 3b).

4.

Secure the upper mounting bracket. Holes are provided on the

appliance for securing the angle bracket in place. Secure the

mounting bracket to the top of the appliance and the underside

of the work surface (fig. 3c).

5.

Connect the fan motor cable with the fan. The socket can be

found on the front side of the fan near the base of the

housing. (fig. 4a).

6.

Screw the fan housing to the appliance above the opening.

(fig. 4b).
Note: The fan housing can alternatively be fitted to the rear of

the appliance.
To do this, unscrew the cover panel on the rear of the

appliance and fit it to the front of the appliance.
The fan motor cable must also be routed through the rear of

the appliance.

7.

Secure the control unit to the appliance next to the fan

housing (fig. 5a).

Alternatively, the control unit can be secured on the other side

of the fan motor on the unit wall.
Caution!

Penetrating moisture may result in an electric shock. Do not

secure the control unit to the base of the fitted unit.

8.

Connect the connecting cable (fig. 5b). Firmly insert the control

cable from the control unit into the appliance. The plug must

snap into place. Connect the control unit to the mains and

check that it works correctly. If the appliance does not work:

Check that the connection cable is positioned correctly.

Removing the appliance

1.

Disconnect the appliance from the power supply.

2.

Loosen the screw connections with the unit.

3.

Unscrew the attachment parts of the appliance.

4.

Push out the appliance from below.

Caution!

Danger to the appliance. Do not lift up the appliance from

above.

fr

Þ

Notice de montage

:

Précautions de sécurité importantes

Lire attentivement ce manuel. Ce n'est qu'alors que vous

pourrez utiliser votre appareil correctement et en toute sécurité.

Conserver la notice d'utilisation et de montage pour un usage

ultérieur ou pour le propriétaire suivant.
La sécurité de l’appareil à l’usage est garantie s’il a été encastré

conformément à la notice de montage. Le monteur est

responsable du fonctionnement correct sur le lieu où l'appareil

est installé.
La largeur de la hotte aspirante doit équivaloir à celle de la table

de cuisson.
L’installation doit avoir lieu en respectant les prescriptions

actuellement en vigueur dans le bâtiment, ainsi que les

prescriptions publiées par les compagnies distributrices

d’électricité et de gaz.
Danger de mort !

Il y a risque d'intoxication par réaspiration des gaz de

combustion.
En cas d'utilisation simultanée de l'appareil en mode évacuation

de l'air et d'un foyer à combustion alimenté en air ambiant,

veillez impérativement à ce que l'apport d'air soit suffisant.

Les foyers à combustion alimentés en air ambiant (par exemple

appareils de chauffage, au gaz, au bois, au fioul ou au charbon,

les chauffe-eau, chauffe-eau accumulateurs) prélèvent l'air de

combustion dans la pièce où ils sont installés et rejettent les gaz

de fumée à l'extérieur par le biais d'un système spécifique

(cheminée par exemple).
Lorsque la hotte aspirante est en marche, elle prélève de l'air

dans la cuisine et dans les pièces voisines ; si l'apport d'air frais

est trop faible, une dépression se forme. Des gaz toxiques

provenant de la cheminée ou du conduit d'évacuation sont

réaspirés dans les pièces d'habitation.

Il faut donc toujours s'assurer que l'apport d'air frais est

suffisant

La présence d'une ventouse télescopique d'apport et

d'évacuation d'air ne suffit pas à assurer le respect de la

valeur limite.

Le fonctionnement sûr de l'appareil n'est possible que si la

dépression dans la pièce où est installé le foyer ne dépasse pas

4 Pa (0,04 mbar). On y parvient en présence d'ouvertures non

obturables ménagées par ex. dans les portes, fenêtres et en

association avec des ventouses télescopiques d'admission/

évacuation de l'air à travers la maçonnerie ou par d'autres

mesures techniques permettant à l'air d'affluer pour assurer la

combustion.

Demandez toujours conseil au maître ramoneur compétent qui

pourra évaluer l'ensemble du réseau de ventilation de la maison

et vous proposer le moyen le mieux adapté pour l'aération.
Si la hotte aspirante est utilisée exclusivement en mode

recyclage, le fonctionnement est possible sans restrictions.
Danger de mort !

Il y a risque d'intoxication par réaspiration des gaz de

combustion. Lors de l'installation d'une ventilation avec un foyer

relié à une cheminée, l'alimentation électrique de la hotte doit

être munie d'un circuit de sécurité approprié.