2 alarm contact and relay connections – Videotec ULISSE User Manual

Page 22

Advertising
background image

EN - English - I

nstruc

tions manual

20

7.2.5 Connecting the Ethernet cable
(for IP board version only)

To connect the net cable a UTP, Category 5E or
superior, 4 pair with a max length of 100m. is needed.

j

Telemetry transmission and video signal
pass through the Ethernet cable. Do not
connect cable RS485 and the video cable.

Crimp the RJ45 connector on the ethernet cable.
Crimping should be straight-through if passing via
a hub or switch while it should be crossover if you
are connecting directly to the PC for the necessary
checks.
Connect the crimped net cable to connector RJ45
located on the base of the unit.

Fig. 34

The example below shows a typical installation.

Hub / Switch

Personal

Computer

UTP cat 5E

UTP cat 5E

Fig. 35

RS232

Fig. 32

7.2.4.2 Alarm contact and relay connections

Signal

Vdc

O1 C1

O2 C2

+

V

Fig. 33

TERMINALS

DESCRIPTION

F1-F2

Additional lines

O1-C1 and
O2-C2

Clean output contacts, can be activated by
alarm or by user control

AL1, AL2, AL3,
AL4 and COM

Live controlled alarm inputs referring to
common COM

Tab. 07