Anetsberger Brothers CF14 User Manual

Page 12

Advertising
background image

12

FR

FR

FR

FR

FRYER

YER

YER

YER

YER TR

TR

TR

TR

TROUBLESHOO

OUBLESHOO

OUBLESHOO

OUBLESHOO

OUBLESHOOTING GUIDE

TING GUIDE

TING GUIDE

TING GUIDE

TING GUIDE

(Continued)

PROBLEM

CAUSE

REMEDY

Pilot flame goes out
repeatedly.

1. Low gas supply pressure [less than 6”

W.C. for natural gas; (11” W.C. for pro-
pane) when all other gas-powered kitchen
equipment is operating].

2. Loosen thermopile or high-limit thermo-

stat connection(s) on gas control valve.

3. Pilot flame does not continuously touch

the thermocouple because of excessive
air flow around the pilot burner assembly.

4. High-limit thermostat problem has shut off

the gas.

1. Measure the gas supply pres-

sure.
Contact your local gas supplier
to obtain adequate gas supply
pressure.

2. Check and tighten the connec-

tions.

3. Block the excessive air flow to

make the pilot flame contact
the thermocouple.

4. Check for, and repair, any dam-

aged high-limit thermostat wir-
ing.

Test the high-limit thermo-

stat by disconnecting the ther-
mocouple at the gas control
valve. Then, disconnect the red
wires to the high-limit thermo-
stat from the gas control valve.
Reconnect the thermopile;
next, perform the Lighting Pro-
cedure, to check whether the
pilot flame lights. If the pilot
flame stays lit, the high-limit
thermostat has failed and must
be replaced.

Pilot flame does not
stay lighted.

(Continued)

6. High-limit thermostat problem has shut off

the gas. (Continued)

7. Gas control valve has failed.

6. Check for, and repair, any dam-

aged high-limit thermostat wir-
ing. Test the high-limit thermo
stat by disconnecting the
thermopile at the gas control
valve. Then, disconnect the red
wires to the high-limit thermo
stat from the gas control valve.
Reconnect the thermopile;
next, perform the Lighting Pro-
cedure, to check whether the
pilot flame lights. If the pilot
flame stays lit, the high-limit
thermostat has failed and must
be replaced.

7. Replace the gas control valve.

CAUTION: DO NOT return
the fryer to normal operation
with its high-limit thermostat
bypassed/disconnected.

!

!

CAUTION: DO NOT return
the fryer to normal operation
with its high-limit thermostat
bypassed/disconnected.

Advertising