Figure 1. Fryer Model CF14 Wiring Diagram

Figure 1 is a wiring diagram of an

ANETS

ANETS

ANETS

ANETS

ANETS CF14 Fryer. Some fryers
may have other options that do not
appear in this basic wiring diagram. A
model-specific wiring diagram included
with each fryer shows all the actual parts
and their associated wiring connections.

FRYER ELECTRICAL SPECIFICATIONS

The

ANETS

ANETS

ANETS

ANETS

ANETS Fryer Model CF14 requires no external electric power source.

IMPORTANT: Read the Code Requirements
and ALL installation instructions carefully,
before starting the installation. Contact the
factory if any problems or questions arise.

The fryer installation must conform with local
codes, or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1 (latest
edition); the Natural Gas Installation Code, CAN/
CGA-B149.1 (latest edition); or the Propane Gas
Installation Code, CAN/CGA-B149.2 (latest
edition), as applicable, including:

a. Disconnect the fryer and its individual shutoff

valve from the gas supply piping system during
any pressure testing of the gas supply system at
test pressures in excess of ½ psig (3.45 kPa).

b. Isolate the fryer from the gas supply piping

system during any pressure testing of the gas
supply system at test pressures equal to or
less than ½ psig (3.45 kPa).

c. Install this fryer on a non-combustible surface

with its back and sides at least 6” away from
any combustible wall, as shown in Figure 2.

d. Install this fryer in a location where adequate

combustion and ventilation air is available.
Keep the area directly in front of the fryer
open for adequate air flow to the burners. DO
NOT
obstruct the flow of combustion and
ventilation air.

h. Keep the fryer area free and clear from

combustibles and debris.

CODE REQUIREMENTS

CODE REQUIREMENTS

CODE REQUIREMENTS

CODE REQUIREMENTS

CODE REQUIREMENTS

!

WARNING

Install this fryer under a ventilation

hood that conducts combustion pro-

ducts outside the building. Venting

must comply with ANSI/NFPA 96

(latest edition).