PRINTER or DVR OUTPUT

There may be situations where you do not want tellers or other employees to know what triggers an exception. In this
case, the VSSI-Pro provides a seperate output that will send data to a remotely located serial printer. If you turn the on-
screen display off and the output on and you have a remote serial printer hooked up to the VSSI-Pro, then whenever an
exception is reported it is sent out to the serial printer only. The printer will give you a hard copy printout of the question-
able transaction with the time and date. With this hard copy printout of the exception report, you can then review the
recording by going directly to that exception's time.

The serial printer output of the VSSI-Pro can be programmed to send out the entire transaction. The output can be
connected to other equipment such as DVRs, phone line transmissions, or digital storage devices for later retrieval or
using search functions built into these devices.

On the main-menu, press the “Up” or “Down” button to move the cursor to “EXCEPTION REPORT” and press “Set”. The
following sub-menu will appear:

PROGRAMMING THE VSSI-PRO

Figure 33: EXCEPTION REPORT Sub-Menu

EXCEPTION HISTORY
SET EXCEPTION
OUTPUT

ON

TIME STAMP

ON

EXIT

Figure 34: EXCEPTION HISTORY Sub-Menu

TOTAL EXCEPTIONS

000

VIEW EXCEPTIONS
DVR SELECTION
TIME SEARCH
OUTPUT EXCEPTIONS
CLEAR HISTORY
EXIT

EXCEPTION HISTORY

Press the “Up” or “Down” button to move the cursor to “EXCEPTION HISTORY” and press “Set”. The following sub-menu
will appear:

TOTAL EXCEPTIONS

This is not a selection, it simply displays the total exception count kept in the Exception History Buffer.

VIEW EXCEPTIONS

This displays the buffered exceptions on-screen, starting with the oldest exception in the buffer. Press the “Up” or “Down”
button to move the cursor to “VIEW EXCEPTIONS” and press “Set”. Once in the exception displaying screen, press the
“Up” or “Down” button to scroll to the next screen. Press “Set” to exit and return to the previous menu. Remember, you
must turn the DISPLAY “ON” for exceptions to be saved in history.