Frequency Output Signal

Flowmeter

Flow Sensor

Variable Speed Drive

Controller

Transmitter

Frequency Output Signal

Flow Meter

Line Frequency

Variable Speed Drives

Connection for signals with amplitudes below 10.25V RMS

Connection for signals with amplitudes to 250 V RMS

COUNT FREQUENCIES

OPERATING INSTRUCTIONS

28

COUNT FREQUENCIES

Choose this function to use the 830-KP as a frequency counter.
Available ranges are from 0.01 to 15.00 kHz, 1 to 1500 Hz and
from 1 to 1500 CPM (Counts-Per-Minute).
To measure waveforms with amplitudes between 1 V and 10.25 V
RMS use the low level inputs. Use the high voltage connection to
read waveforms with amplitudes from 10.25 to 250.0 V RMS

1) Disconnect one or both input wires from the device to be

calibrated

2) Press the FREQUENCY/PRESSURE pushbutton until any

frequency signal (KHz, Hz or CPM) appears on the display.

3) Press the DISPLAY/SOURCE/READ push-button until READ

and KHz, Hz or CPM appear on the display

4) Press the TYPE/ENG UNITS push-button to select between KHz,

Hz or CPM on the display

5) Connect the red READ lead of the calibrator to the plus (+) input

of the device and the black READ lead to the minus (-)

OPERATING INSTRUCTIONS