15

WARNING / DANGER / CAUTION!

Before connecting equipment, make sure that

all the components

used are suitable for the maximum operating pressure of the

pump unit. In cases of doubt, you must consult LUKAS directly.

To protect against dust, the accompanying dust protection caps must be replaced.

REMARK:

Hoses can be connected only when

depressurised.

CAUTION!

Always connect the return hose first and then the supply hose.

Before coupling, remove the dust protection caps, then pull back and hold the locking sleeve

of the female coupling (position X). Fit the socket and plug together and release the locking

sleeve. Then turn the locking sleeve to position Y. The connection has now been made and

locked. Disconnection is made in the reverse order. Hoses can be connected only when

depressurised. To protect against dust, the accompanying dust protection caps must be

replaced.

5.2 Connection of quick-connect couplings

The device connects to the hydraulic pump by means of individually coded quick-connect

coupling halves (plug and socket).

X

WARNING / DANGER / CAUTION!

Some quick-disconnect couplings have special functions. Therefore it is not

permitted

to screw them off the hoses or to swap them.