11.3 Control desk (control unit + pedestal)

Designation

CT7-6/3DV

CT7-6/4DV

CT7-6/4DVV

(with pedestal)

(with pedestal)

(with pedestal)

Ref. no.

840721341

840721342

840721343

Comprising:

(ref. nos.)

840721344

840721345

840721346

840720325

840720325

840720325

Dimensions

(L x W x H)

[mm]

801 x 700 x 1100 931 x 700 x 1100 986 x 700 x 1100

[in.]

35.5 x 27.6 x 43.3 36.7 x 27.6 x 43.3 38.8 x 27.6 x 43.3

Weight

[kg]

44,5

52,0

59,3

[lbs.]

98.1

114.6

130.7

11.4 Recommended hydraulic fluids

Mineral oil DIN ISO 6743-4 for LUKAS hydraulic equipment and others

Oil temperature range

Oil code

Viscosity rating

Remarks

A

-24 .... +30°C

HL 5

VG 5

B

-18 .... +50°C

HM 10

VG 10

C

-8 .... +75°C

HM 22

VG 22

D

+5 .... +80°C

HM 32

VG 32

E

-8 .... +70°C

HF-E15

VG 15

Bio-oil

Oil temperature range

Oil code

Viscosity rating

Remarks

A

-11.2 .... +86°F

HL 5

VG 5

B

-0.4 .... +122°F

HM 10

VG 10

C

+17.6 .... +167°F

HM 22

VG 22

D

+41.0 .... +176°F

HM 32

VG 32

E

+17.6 .... +158°F

HF-E15

VG 15

Bio-oil

recommended viscosity range: 10...200 mm²/s

(10…200 cSt.)

Supplied with HM 22 DIN ISO 6743-4.

11.5 Operating temperature and storage temperature ranges

Operating temperature

[°C]

-20 …

+55

Ambient temperature

(device in operation)

[°C]

-25 …

+45

Storage temperature

(device not in operation) [°C]

-30 …

+60

Operating temperature

[°F]

-4 …

+131

Ambient temperature

(device in operation)

[°F]

-13 …

+113

Storage temperature

(device not in operation)

[°F]

-22 …

+140