Lukas LAA Pulling Device User Manual

Page 7

Advertising
background image

7

10400

When the pulling cylinder is fully extended, you can continue with pulling without any manual

resetting: switch the control valve to "lowering", and the pulling cylinder will be retracted without
a movement of the pulling rope.
As the pulling rope latches automatically, the pulling procedure
can be started again as soon as the pulling cylinder is in fully retracted position.
The "pull and retract" procedure can be repeated as long as sufficient pulling rope is available.

11000 Dismantling of the device

11100

Make sur that pulling rope and holding ropes are no longer under tension. If necessary,

release tension from the ropes by advancing and retracting the pulling cylinder.

11200

Set the control valve on the control table to middle position and switch the motor pump

off.

11300

Uncouple the red hose first, and then the blue hose.

11400

Remove the fixing bolts for the holding ropes on pulling cylinder and rail attachments and

remove the holding ropes.

11500

Unlatch the pulling rope arresting mechanism as described under 8300 and pull the rope

completely out of the pulling cylinder.