VerifyNow System User Manual |

USA

Term

Description

Detection well

The detection wells of an test device contain a lyophilized preparation of human

fibrinogen coated beads and platelet agonist. The instrument measures platelet

aggregation as an increase in light transmittance through the detection wells.

Diluent

An optically absorbent solution used in lieu of blood during wet quality control.

Diluent tube

Tube in the VerifyNow Assay WQC kit (part number 85047) containing the diluent.

Discard tube

When collecting patient samples using direct venipuncture, the discard tube (that

is later discarded) is filled before the sample tube. This tube may be plain sodium

citrate, blood culture, or heparin tube. The tube cannot contain EDTA (purple top).

Electronic

quality control

Electronic quality control (EQC) is a procedure during which the software will

calibrate and verify instrument optics performance, reagent mixing, and instrument

pneumatics.

EQC

See electronic quality control.

EQC device

A re-usable device that is inserted by the operator into the test port and is used

to perform a comprehensive testing routine that confirms performance of key

instrument components.

EQC frequency

Specifies the time interval between EQC tests. When the time interval is exceeded,

the instrument cannot perform patient testing until an EQC test is performed.

Eptifibatide

Eptifibatide (trade name Integrilin

®

) is a platelet aggregation inhibitor mainly used

during and after coronary artery procedures like angioplasty to prevent thrombus

(blood clot) formation within the coronary artery. Its mechanism of action is

inhibition of the glycoprotein IIb/IIIa complex.

Error

A type of message that displays after an unexpected event. Typically these events

occur when the instrument detects an abnormal condition, and often can be

corrected by the customer.

F1

The mixer frequency flag count parameter reported during electronic quality control

diagnostics. See electronic quality control.

F2

The mixer frequency transitions (high to low) parameter reported during electronic

quality control diagnostics. See electronic quality control.

Fibrinogen

A soluble blood plasma protein which the enzyme thrombin converts into fibrin

during the blood-clotting process. The binding of the activated platelet IIb/IIIa

receptors to fibrinogen (and vWF) results in the formation of platelet-platelet and

platelet-matrix adhesive interactions and the formation of a stable, larger platelet

aggregate.

glycoprotein

(GP) IIb/IIIa

receptor

Activation induces a conformational change in the platelet glycoprotein IIb/IIIa

receptors on the surface of platelets to an activated high-affinity binding site for

fibrinogen and vWF. The binding of the activated platelet IIb/IIIa receptors to

fibrinogen (and vWF) results in the formation of platelet-platelet and platelet-matrix

adhesive interactions and the formation of a stable, larger platelet aggregate at the

site of injury.

Icon

Icons are used to navigate through the steps in a test. Icons display along the right

side of the display screen and correspond to an adjacent icon key.

Icon keys

The four icon keys directly to the right of the display screen correspond to the

different icons displaying on the screen. Selecting an icon key displays another

screen or directs the instrument to perform an action.