Clip ‘n’ fit, Board – Qmark GFR Series - Fan-Forced Wall Heaters User Manual

Page 3

Advertising
background image

3.

If the thermostat is controlling more than one heater, the total
of all heater amperage ratings (Table 1) cannot exceed 25

amps at 120 volts AC thru 240 volts AC. Refer to Table

2 for

correct wire, circuit breaker, or fuse sizing.

4.

Connect one red and one black thermostat lead to power
wiring per wiring diagram (Fig. 6) using properly sized listed
wirenuts (provided).

5.

Fold wires back into wiring compartment behind thermostat
to clear fan deck.

TO INSTALL FAN DECK ASSEMBLY

NOTE:

Fan deck assembly should not be installed until after the

drywall phase of construction is complete. Dust from drywall
installation and joint compound can be harmful if it gets inside fan
deck components.

1.

Locate fan deck and mounting rails in top of back box.

2.

Insert flanges on fan deck into mounting rails and slide back
until fan deck stops (see Fig. 7).

3.

Make wiring connections, attaching one red and one black
thermostat lead to two (2) black heater leads for 240V or to
black and white heater leads for 120V with wirenuts
(provided). Connect field ground lead to bare ground wire
with wirenut (provided). See Fig. 6.

4.

Remove 1/2” knockout from grille and install grille using two
oval head screws. Push thermostat knob on thermostat
shaft.

5.

Reconnect power at main fuse or circuit breaker distribution
panel.

3

Figure 6

TABLE 2

TOTAL AMPS

0 thru 12

12.1 thru 16
16.1 thru 24

WIRE SIZE

(COPPER)

#14
#12
#10

CIRCUIT BREAKER

OR FUSE SIZE

15 Amps
20 Amps
30 Amps

TO CHANGE WATTAGE OUTPUT

The chart shows the wattages available by model. Each heater
is factory wired for its maximum wattage. The last two columns
in the chart refer to the jumpers on the CLIP ‘n’ Fit

®

Board. To

change wattage, clip out Jumper 1 and/or Jumper 2 as shown in
the chart below. Completely remove jumpers by clipping at both
ends as close to the board as possible.

Figure 5

TOP OF BACK BOX

FLANGE ON FAN DECK

MOUNTING RAIL

Figure 7

WATTAGE

JUMPER

1

JUMPER

2

2400
1800
1200

600

1800
1350

900
450

2000
1500
1000

500

1500
1125

750
375

1500
1125

750
375

Red

Jumper

Leave in
Leave in

Clip out
Clip out

Blue

Jumper

Leave in

Clip out

Leave in

Clip out

R2404 &

R2404T2

@240V @208V

R2004 &

R2004T2

@240V @208V

R1500 &

R1500T2

@120V

R Series only

RT2 Series only

TABLE 1

MODEL

R1500

R1500T2

R2004

R2004T2

R2404

R2404T2

VOLTS

120

240
208
240
208

WATTS/AMPS

1500W/12.5A

2000W/8.3A

1500W/7.2A

2400W/10.0A

1800W/8.7A

WATTS/AMPS

1125W/9.4A

1500W/6.3A

1125W/5.4A

1800W/7.5A

1350W/6.5A

WATTS/AMPS

750W/6.3A

1000W/4.2A

750W/3.6A

1200W/5.0A

900W/4.3A

WATTS/AMPS

375W/3.1A

500W/2.1A

375W/1.8A

600W/2.5A

450W/2.2A

Note:

“IF” Inner Frame models must be used with RBB Back

box.

Clip ‘n’ Fit

®

Board

BLUE

JUMPER

RED

JUMPER

BACK BOX

END CAP

HOLE

Figure 4

End View

®

Advertising