2.4 PROGRAMMABLE AND OPERATIONAL FUNCTIONS

SINGLE ENTRY PARAMETERS AND FUNCTIONS

FUNCTION

RANGE

WELD TYPE (PULSED, NON-PULSED, STEP,
TACK, S^3)

SELECTABLE

NUMBER OF LEVELS

1 - 99 LEVELS

START CURRENT

5 - 150 AMPS

PREPURGE

10 - 1000 SECONDS

POSTPURGE

10 - 1000 SECONDS

TRAVEL START DELAY

0.0 - 100 SECONDS

TRAVEL DIRECTION

CW or CCW


MULTI-LEVEL PARAMETERS AND FUNCTIONS

The following parameters and functions can be programmed in each level to change
value during a weld sequence.

DOWN SLOPE

0.0

– 99.9 SECONDS

LEVEL TIME

0.0

– 999.9 SECONDS

PRIMARY (HIGH) AMPS*

5

– 150 AMPS

BACKGROUND (LOW) AMPS

5

– 150 AMPS

SLOPE TIME

CANNOT EXCEED LEVEL TIME

PRIMARY SPEED (RPM)

0.0 RPM TO WELD HEAD MAX.**

PRIMARY SURFACE SPEED

(INCHES PER MINUTE)

CALCULATED

AVERAGE AMPS

CALCULATED

FREQUENCY (Hz.)

CALCULATED

% PRIMARY AMPS

1%

– 100%

PRIMARY (HIGH) PULSE TIME

0.01

– 9.99 SECONDS

BACKGROUND (LOW) PULSE TIME

0.01

– 99.9 SECONDS