M O D E L 2 1 7 W D R
O P E R A T O R ’ S M A N U A L

16

WELD SCREEN

From the Weld Screen the operator has access to all power supply, welding and weld
head functions at a touch of the weld screen:

START: Starts the Weld sequence. (Pre purge, arc start, weld sequence, post purge,
rotor returns home, finish weld).

STOP: Terminates weld sequence. (Arc off/rotation stops, post purge, rotor returns
home, finish).

TEST: Starts Test Run sequence. (No purge, no arc, weld schedule sequence, rotor
returns home, finish).

HOME: Manual rotor Return Home command.

PURGE: Manual ON/OFF override of Arc Gas solenoid. (Command to open and close
gas solenoid for setting initial flow rate or continuous arc gas purge flow).

JOG FWD: Allows manual forward rotation of the rotor. Stops when released.

JOG REV: Allows manual reverse rotation of the rotor. Stops when released.

PRINT SCHEDULE: Provides printout of entire weld schedule parameters.

CALIBRATE: If weld heads differ when changing weld schedules, provides automatic
weld head calibration to power supply. Follow on screen prompts to perform calibration.