Safety directions – Leica Geosystems TPS1100 Professional Series - User Manual User Manual

Page 134

Advertising
background image

134

TPS1100 - User Manual 2.2.1en

Safety directions

6

Exit for laser
beam
(visible)

Integrated distancer (visible laser), continued

1100Z33

Automatic target recognition (ATR)

The integrated automatic target
recognition produces an invisible
laser beam which emerges coaxially
from the telescope objective.

The product is a Class 1 laser
product in accordance with:
• IEC 60825-1:1993 "Radiation

safety of laser products".

• EN 60825-1:1994 + A11:1996

"Radiation safety of laser
products"

The product is a Class I laser product
in accordance with:
• FDA 21CFR Ch.I §1040: 1988 (US

Department of Health and Human
Service, Code of Federal
Regulations)

Class 1/I laser products are safe
under reasonably foreseeable
conditions of operation and are not
harmful to the eyes provided that the
products are used and maintained in
accordance with the instructions.

Beam divergence: 0.15 x 0.35 mrad
Pulse duration:

800 ps

Maximum radiant
power:

0.95 mW

Maximum radiant
power per pulse:

12 mW

Measurement
uncertainty:

± 5%

Beam divergence:

26.2 mrad

Pulse duration:

9.8 ms

Maximum radiant power: 0.76 mW
Maximum radiant power
per pulse:

1.52 mW

Measurement uncertainty: ± 5%

Class 1 Laser Product

according to IEC 60825-1:1993

Advertising