68 system functions – Leica Geosystems TPS1100 Professional Series - User Manual User Manual

Page 68

Advertising
background image

68

System functions

TPS1100 - User Manual 2.2.1en

Activates the tracking mode if
the measuring program

"Standard distance measurement"
was selected, or the rapid-tracking
mode if the measuring program "Fast
distance measurement" was
selected.

Calls the EDM test (signal
and frequency)

Stops the current measuring
program.

Calls the function " EDM
parameters".

Distance measurement, continued

Selecting the EDM measuring program, target type and reflector

\

EDM parameters

Set EDM Prog for DIST/ALL

Target Typ :

IR=Reflector

EDM Prog. :

Standard IR

Refl.Name : Leica circ.prism

Add.const.:

0.0 mm

CONT

REFL

MC

QUIT

Infrared:

Standard IR
Normal distance measurement.
Accuracy 2mm+2ppm.
Measuring time 1.0 seconds.

Standard Fast IR
Rapid distance measurement.
Accuracy 5mm+2ppm.
Measuring time 0.5 seconds.

Tracking IR
Continuous measurement.
Accuracy 5mm+2ppm.
Measuring time 0.3 seconds.

Tracking Fast IR
Continuous measurement.
Accuracy 10mm+2ppm.
Measuring time <0.15 seconds.

Average IR
Repeat measurements in standard
measuring mode with display of the
number of distance measurements
(2

n

999), the current average and

the standard deviation for the
averaged distance.

Very short distances may
be measured reflectorless

in Infrared-mode (e.g. to well
reflecting targets like traffic signs).
In this case the distances are
corrected with the addition
constant defined for the active
reflector.

Reflector-free and long range:
(red laser)

Standard Long RL
Normal distance measurement.
Accuracy 3mm+2ppm.

Average Long RL
Repeat measurements in normal
measuring mode

Advertising