3

INSTALLING AND TIGhTENING STOP LOCkNuTS

Objective: Install locknuts for check stops and thermal cartridge.

Place thermal valve body on table with cold inlet on the right and hot inlet on the left.

Install hot and cold check stop lock nut by placing over top of check stop and tighten to a snug fit
using a

13

16

" socket wrench and ratchet.

Figure 3.1

Install cartridge locknut by placing over top of thermal cartridge and tighten to a snug fit using 1¼"
socket wrench and ratchet.

Figure 3.2

Note: After tightening the locknut on thermal cartridge, verify that the cartridge did not turn
from the 12 o'clock position. Adjust as necessary.

Figure 3.3

3.1

3.2

3.3

J-TH34 | PG 4

Black tic mark is aligned with (S)
on north side of valve.